Notifiche
Cancella tutti

L9- Acronimi RM

6 Post
1 Utenti
0 Reactions
1 Visualizzazioni
(@Utente 0002)
Registrato: 1 secondo fa
Post: 0
  [#1703]

Di seguito sono elencati i nomi utilizzati dalle diverse case costruttrici per le varie sequenze.

Spin Echo
SE per tutte le case costruttrici.

Turbo Spin Echo / Fast Spin Echo
FSE : GE, HITACHI, TOSHIBA
TSE: PHILIPS, SIEMENS

Single Shot TSE
SSFSE: GE, HITACHI
SSFSE: PHILIPS
HASTE: SIEMENS
FASE: TOSHIBA

FSE/TSE con preimpulso 90°
FRFSE: GE
Driven Equilibrium FSE: HITACHI
DRIVE: PHILIPS
RESTORE: SIEMENS
FSE T2 puls: TOSHIBA

IR
fastIR: GE
TIR: tutte el altre case costruttrici
STIR: tutte le case costruttrici
FLAIR tutte le case costruttrici ad esclusione di SIEMENS (Dark Fluid)

Gradient Echo
GRE: GE, SIEMENS
GE: HITACHI
FFE: PHILIPS
Field Echo: TOSHIBA
Gradient eco (coerente): GRASS(GE), Rephased SARGE o GFEC (HITACHI), FFE (PHILIPS), FISP (SIEMENS)
Gradiet eco (RF spoiled) : SPGR(GE), GE/GFE (HITACHI) , T1 FFE (PHILIPS), Field Echo (TOSHIBA)
Gradient eco (gradient spoiled) MPGR (GE), GRE(HITACHI), T1-FAST(PHILIPS), FLASH (SIEMENS), Field Echo (TOSHIBA)
Steady State: SSFP o DEFGR(GE), T2 FFE (PHILIPS), PSIF (SIEMENS)
Balanced Sequence True Fisp: FIESTA(GE), Balanced FFE(PHILIPS), BASG(HITACHI), TrueFISP(SIEMENS), True SSFP(TOSHIBA)
Dual Excitation True FISP : FIESTA-C(GE), CISS(SIEMENS)
Multiecho: MEDIC(SIEMENS)
UltrafastGRE: Fast GRE/Fast SPGR(GE), RGE(HITACHI), TFE(PHILIPS),TurboFLASH(SIEMENS), Fast FE(TOSHIBA)
Ultrafast Gradient Echo 3D: 3-D FGRE/3-D Fast SPGR(GE), MPRAGE(HITACHI,SIEMENS), 3D TFE(PHILIPS)
Volume Interpolated GRE: FAME(GE), THRIVE(PHILIPS), VIBE(SIEMENS)
SE+GE: GRASE(GE), TGSE(PHILIPS), Hybrid EPI (TOSHIBA)

Echo Planar Imaging
EPI: per tutte le case costruttrici.

Phase Contrast
PCA: GE, PHILIPS,SIEMENS
VENC: HITACHI

Imaging Parallelo:
SENSE: PHILIPS
ASSET: GE
iPAT : SIEMENS
RAPID: THOSHIBA



   
Citazione
(@Utente 0764)
Registrato: 1 secondo fa
Post: 0
 
Utente 0002 ha scritto:

Di seguito sono elencati i nomi utilizzati dalle diverse case costruttrici per le varie sequenze.

Spin Echo
SE per tutte le case costruttrici.

Turbo Spin Echo / Fast Spin Echo
FSE : GE, HITACHI, TOSHIBA
TSE: PHILIPS, SIEMENS

Single Shot TSE
SSFSE: GE, HITACHI
SSFSE: PHILIPS
HASTE: SIEMENS
FASE: TOSHIBA

FSE/TSE con preimpulso 90°
FRFSE: GE
Driven Equilibrium FSE: HITACHI
DRIVE: PHILIPS
RESTORE: SIEMENS
FSE T2 puls: TOSHIBA

IR
fastIR: GE
TIR: tutte el altre case costruttrici
STIR: tutte le case costruttrici
FLAIR tutte le case costruttrici ad esclusione di SIEMENS (Dark Fluid)

Gradient Echo
GRE: GE, SIEMENS
GE: HITACHI
FFE: PHILIPS
Field Echo: TOSHIBA
Gradient eco (coerente): GRASS(GE), Rephased SARGE o GFEC (HITACHI), FFE (PHILIPS), FISP (SIEMENS)
Gradiet eco (RF spoiled) : SPGR(GE), GE/GFE (HITACHI) , T1 FFE (PHILIPS), Field Echo (TOSHIBA)
Gradient eco (gradient spoiled) MPGR (GE), GRE(HITACHI), T1-FAST(PHILIPS), FLASH (SIEMENS), Field Echo (TOSHIBA)
Steady State: SSFP o DEFGR(GE), T2 FFE (PHILIPS), PSIF (SIEMENS)
Balanced Sequence True Fisp: FIESTA(GE), Balanced FFE(PHILIPS), BASG(HITACHI), TrueFISP(SIEMENS), True SSFP(TOSHIBA)
Dual Excitation True FISP : FIESTA-C(GE), CISS(SIEMENS)
Multiecho: MEDIC(SIEMENS)
UltrafastGRE: Fast GRE/Fast SPGR(GE), RGE(HITACHI), TFE(PHILIPS),TurboFLASH(SIEMENS), Fast FE(TOSHIBA)
Ultrafast Gradient Echo 3D: 3-D FGRE/3-D Fast SPGR(GE), MPRAGE(HITACHI,SIEMENS), 3D TFE(PHILIPS)
Volume Interpolated GRE: FAME(GE), THRIVE(PHILIPS), VIBE(SIEMENS)
SE+GE: GRASE(GE), TGSE(PHILIPS), Hybrid EPI (TOSHIBA)

Echo Planar Imaging
EPI: per tutte le case costruttrici.

Phase Contrast
PCA: GE, PHILIPS,SIEMENS
VENC: HITACHI

Imaging Parallelo:
SENSE: PHILIPS
ASSET: GE
iPAT : SIEMENS
RAPID: THOSHIBA

L'imaging parallelo in toshiba si chiama speeder, Rapid lo chiama hitachi se non mi sbaglio. qualcuno sa come invece hitachi chiama le dual in-out? Non lo trovo da nessuna parte.



   
RispondiCitazione
(@Utente 0840)
Registrato: 1 secondo fa
Post: 0
 

Utilissimo, voi parlate molto spesso in termini Philips, ed io devo riportare su una Siemens ogni tanto mi perdo,



   
RispondiCitazione
(@Utente 0764)
Registrato: 1 secondo fa
Post: 0
 

Su internet trovi gli acronimi pubblicati da Siemens. Sono abbastanza completi.

 

Utente 0840 ha scritto:

Utilissimo, voi parlate molto spesso in termini Philips, ed io devo riportare su una Siemens ogni tanto mi perdo,



   
RispondiCitazione
(@Utente 0191)
Registrato: 1 secondo fa
Post: 0
 
Utente 0764 ha scritto:

L'imaging parallelo in toshiba si chiama speeder, Rapid lo chiama hitachi se non mi sbaglio. qualcuno sa come invece hitachi chiama le dual in-out? Non lo trovo da nessuna parte.

 

RSSG (spoiled GRE). In realtà mi pare che non ci sia un acronimo dedicato per indicare la dual...semplicemente la si costruisce mettendo il doppio TE.. Hitachi è molto aperta da questo punto di vista



   
RispondiCitazione
(@Utente 0764)
Registrato: 1 secondo fa
Post: 0
 

Grazie Utente 0191. Come sempre.



   
RispondiCitazione
Condividi: